BD6000-07 Portable Patient Monitor Details
Model Number
BD6000-07
BD6000-07 Portable Patient Monitor Introduce

Portable(Size is only 185*120*35)

Powerful(All functions are as same as other JP series monitors)

6.4〃Colour TFT LCD(640*480)

Inside Li-Battery and low power waste(Less than 4w)

Can work for 4 hours with battery

BD6000 series patient monitor is competent for the monitoring of the Echocardiograph, Heart Rate,Temperature,Blood Pressure,Respiration and SpO2.

Feature

Portable monitor for 24 hours measurement.

Analysis for arrhythmia and ST segment. Store 96 hours daily data and abnormal data.

Automatic identify NIBP measurement for adult child and baby.

E-Document instruction for operator.

Technical Specification

General

Resist electric shock: Class I Class CF

Apply to: Adult, Child, Baby

Size of Screen: 6.4〞TFT Colour LCD

Resolution: 640*480

Display Waveform: 4 Leads Display waveforms of ECG, Respiration, NIBP SpO2

Colours of Waveform: 15 Kinds

Freeze Waveform: Enable

Monitor Functions: Heart Rate, VPC, Three Level ST Segment,NIBP, SpO2, Pulse Rate, Respiration Rate and Temperature. ECG

Input: 5 Electrode Leads RA, LA, RL, LL, C (V1~V6)

Electrode Lead: StandardⅠ, Ⅱ, Ⅲ; Body Electrode Lead aVR, aVL, aVF; Bosom Electrode Lead V1~V6

Signal Amplifying: 0.5, 0.75, 1.0, 1.5, 2.0 

Range of ECG Measurement: 30 times/min~250 times/min

Precision of ECG: ±5%

Scan Speed: 12.5mm/s, 25mm/s, 50mm/s

ECG Review: Enable

Range of Alarm: 30 times/min~250times/min

Mode of Alarm: Sound and Screen Remind Alarm

Work with electrosurgical unit: Enable

Work with DC: Class CF

Sustain 4000VAC/50Hz electric shock

NIBP

Measure Method: Advanced One-step Method with Automatic / Manual Measurement

Measure Unit: mmHg and kPa

Measure parameter: SYST(systolic pressure), DIAS(diastolic pressure), MEAN(mean arterial pressure)

Measure Range: 10mmHg~280mmHg; 1.3kPa~37kPa

Precision of NIBP: ±5mmHg;±0.7kPa

Protection of Over Pressure: <330mmHg;<44.0kPa

Alarm: SYST, DIAS, MEAN

SpO2

Range of SpO2 Measurement: 40%~99% with the distinction of 1%

Precision of SpO2: During 85%~99%:±2% ; During 60%~85%:±4%

Alarm Range: 0~99%

Measure Pulse Rate Range: 30 Times/min~200 Times/min

Precision of Pulse Measurement: ±5%

Temperature

Measure Range: 32℃~43℃ with the distinction of 1℃

Precision of Temperature Measurement: ±0.2℃

Respiration

Measure Range: 4 Times/min~120 Times/min

Precision of Respiration Measurement: ±2 Times/min

Waveform Display

Waveform Display: Display 4 Waveform in screen.

Trend of data: Store 96 hours chart of data of Heart Rate, NIBP, SpO2, Temperature, Respiration, VPC and ST Segment.

3、Store ECG Waveform: Store 64 waveforms of ECG by every 10 seconds. Can freeze the waveform.

Alarm

Message for the abnormal system alarm of lost lead or too much noise.

Message for the abnormal data alarm of Heart Rate(Tachycardia and Bradycardia), NIBP, Temperature, SpO2, ST Segment(ST Elevation and ST Depression), VPC, Bigeminal rhythm, Tirgeminal rhythm, RonT, VTAC, Escape Beat and Sinus arrest.

Ways of Alarm: Sound and message in the screen.

Alarm Level: 3 levels